Regional standards
GOST and DSTU cable design software
Design to the interstate GOST standards that CIS tenders quote, from GOST 31996 and GOST 34834 to GOST 18410, and to DSTU IEC 60502-1 for Ukraine. Each is a standard of its own, with its tables encoded once and reused in every design.
What you can design
- Power cables from 0.66 to 35 kV: GOST 31996 with plastic insulation, GOST 34834 with XLPE insulation, GOST 18410 with impregnated paper insulation, and DSTU IEC 60502-1:2009
- Overhead lines: GOST 31946 self-supporting and protected wires (СИП-1 to СИП-4) and GOST 839 bare wires
- Control, signalling and cords: GOST 1508 control cables, GOST 31995 block-signalling cables and GOST 7399 cords and flexible wires
- Fire designations to GOST 31565-2012, such as нг(А)-LS and нг(А)-FRHF, derived from the declared fire properties of the design, and the ПБ marking to DSTU 4809:2007
Tabulated GOST currents are kept with the design next to the IEC 60287 calculation, never instead of it. If your tender quotes ST RK, STB or O‘z DSt standards, tell us and we will add them.
Standards in this selection
| GOST 31996-2012 (ГОСТ 31996-2012) | Power cables with plastic insulation, 0.66, 1 and 3 kV, built from the standard's tables on physical diameters, with the core colours of Table 4, the national designation, and the tabulated permissible and short-circuit currents kept with the design next to the IEC 60287 calculation |
| GOST 34834-2022 (ГОСТ 34834-2022) | XLPE insulated power cables 6 to 35 kV: dimensions from the standard's tables, semi-conducting screens, copper wire screen minima and the designation |
| GOST 18410-73 (ГОСТ 18410-73) | Impregnated paper insulated power cables 1 to 35 kV: single-core, belted and separately lead-sheathed, aluminium or lead sheath, protective coverings of Table 1, with IEC 60287 current ratings |
| GOST 31946-2012 (ГОСТ 31946-2012) | Overhead line wires: self-supporting insulated СИП-1, СИП-2, СИП-4 0.6/1 kV and protected СИП-3 20 and 35 kV |
| GOST 839-2019 (ГОСТ 839-2019) | Bare overhead line wires: copper М, aluminium А and АКП, aluminium alloy АН, АЖ, А1, А2, steel-aluminium АС, АСКС, АСКП, АСК, АСца |
| GOST 1508-78 (ГОСТ 1508-78) | PVC control cables КВВГ, КВВГЭ, КВБбШв, copper and aluminium, with insulation to GOST 26411-2024 |
| GOST 31995-2012 (ГОСТ 31995-2012) | PE insulated block-signalling cables in plastic sheath, the 13 types of Table 1 (СБВГ, СБПу, СБПБГ, СБПБбШв and variants), pairs or single cores |
| GOST 7399-97 (ГОСТ 7399-97) | Cords and flexible wires up to 450/750 V: PVC ШВЛ, ПВС, flat ШВВП, ПВСП, rubber ПРС, ПРМ and ПСГ |
| DSTU IEC 60502-1:2009 (ДСТУ IEC 60502-1:2009) | Ukrainian adoption of IEC 60502-1:2004 as a standard of its own: power cables with extruded insulation 1 and 3 kV, dimensional rules compared line by line with the IEC 60502-1:2004 profile |
Missing a standard? We add it to the library on request. Tell us which one.